Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters








Year range
1.
Einstein (Säo Paulo) ; 13(2): 319-325, Apr-Jun/2015. graf
Article in English | LILACS | ID: lil-751435

ABSTRACT

ABSTRACT Given the shortage of organs transplantation, some strategies have been adopted by the transplant community to increase the supply of organs. One strategy is the use of expanded criteria for donors, that is, donors aged >60 years or 50 and 59 years, and meeting two or more of the following criteria: history of hypertension, terminal serum creatinine >1.5mg/dL, and stroke as the donor´s cause of death. In this review, emphasis was placed on the use of donors with acute renal failure, a condition considered by many as a contraindication for organ acceptance and therefore one of the main causes for kidney discard. Since these are well-selected donors and with no chronic diseases, such as hypertension, renal disease, or diabetes, many studies showed that the use of donors with acute renal failure should be encouraged, because, in general, acute renal dysfunction is reversible. Although most studies demonstrated these grafts have more delayed function, the results of graft and patient survival after transplant are very similar to those with the use of standard donors. Clinical and morphological findings of donors, the use of machine perfusion, and analysis of its parameters, especially intrarenal resistance, are important tools to support decision-making when considering the supply of organs with renal dysfunction.


RESUMO Diante da escassez de órgãos para transplante, algumas estratégias têm sido adotadas pela comunidade transplantadora, no sentido de ampliar a oferta de órgãos. Uma delas é a utilização de rins de doadores com critérios expandidos, ou seja, doadores com idade >60 anos ou entre 50 e 59 anos, e que atendem a dois ou mais dos seguintes critérios: história de hipertensão, creatinina sérica terminal >1,5mg/dL e acidente vascular cerebral como causa de morte do doador. Nesta revisão, foi dada ênfase à utilização de doadores com disfunção renal aguda, condição considerada por muitos uma contraindicação para a aceitação de órgãos e, portanto, uma das principais causas de descarte de órgãos. Desde que sejam doadores bem selecionados e que não tenham doença renal crônica, como hipertensão ou diabetes, muitos trabalhos mostraram que o uso de doadores com disfunção renal aguda deve ser encorajado, pois, em geral, a disfunção renal aguda é de caráter reversível. Embora, a maioria dos estudos tenha demonstrado que há uma maior taxa de função retardada do enxerto com a utilização desses órgãos, os resultados de sobrevida do enxerto e do paciente após o transplante são muito semelhantes aos resultados obtidos da utilização de doadores padrão. Os achados clínicos e morfológicos do doador, a utilização da máquina de perfusão e a análise de seus parâmetros, principalmente a resistência intrarrenal, são importantes ferramentas de apoio para tomada de decisão no momento da oferta de órgãos com disfunção renal.


Subject(s)
Aged , Humans , Middle Aged , Acute Kidney Injury/surgery , Graft Survival , Kidney Failure, Chronic/mortality , Kidney Transplantation/methods , Patient Selection , Tissue Donors/supply & distribution , Age Factors , Creatinine/blood , Delayed Graft Function/mortality , Donor Selection/organization & administration , Graft Survival/physiology , Kidney Failure, Chronic/surgery , Kidney Transplantation/mortality , Length of Stay/statistics & numerical data , Survival Rate
2.
Einstein (Säo Paulo) ; 7(4)2009. graf, ilus, tab
Article in Portuguese | LILACS | ID: lil-541618

ABSTRACT

Objective: To evaluate the incidence of antibody-mediated rejection after the C4d and donor specific antibody detection was provided by Luminex in renal transplantation biopsies; to compare acute antibody-mediated rejection characteristics as related to acute cellular rejection; to evaluate the impact on the incidence of acute antibody mediated rejection after the utilization of cross match test by flux cytometry and the detection of pre-transplantation donor specific antibody in patients with previous history of exposition to alloantigens. Methods: One hundred twenty-four renal transplanted patients were evaluated through the detection of C4d in early biopsies of those presenting graft dysfunction and the detection of antibody against donor when C4d was positive. The acute antibody mediated rejection was treated by plasmapheresis and intravenous immunoglobulin. Results: The incidence of acute rejection was 18.8%, being the acute cellular rejection 14.9% and acute antibody mediated rejection 6.6%. When both were compared, the acute antibody-mediated rejection were earlier than the acute cellular rejection (12.5 versus 59.9 days, p = NS), being more frequent in female patients (75 versus 29%, p = 0.05), with deceased donors (75 versus 33%, p = 0.09), with higher dialysis time (87.7 versus 47.4, p = 0.03), greater number of transfusion episodes (4.6 versus 1.4, p = 0.02), greater panel reaction activity (28.0 versus 4.8, p = 0.03) and more frequently in re-transplanted patients (50 versus 5.6%, p = 0.02). Delayed graft function was more frequent in antibody mediated rejection (100 versus 50%, p = 0.02). All patients with acute cellular rejection reversed graft function after treatment, with 100% graft survival after one year. Among patients with acute antibody-mediated rejection, the treatment with plasmapheresis and immunoglobulin was efficient in reducing the titers of donor specific antibody (2605 versus 202 mfi, p < 0.001), but 3/8 of patients evolved to graft loss, making graft survival of 62.5% (p < 0.001). Conclusions: The routine use of detecting C4d and donor specific antibody increased the incidence of acute rejection. Acute antibody-mediated rejection presented clinical profile and therapeutic response different from acute cellular rejection, identifying a worse prognosis as well as therapeutic success.


Objetivo: Avaliar a incidência da rejeição mediada por anticorpo depois de instituída a pesquisa de C4d em biópsias de rim transplantado e pesquisa de anticorpo específico de doador pelo Luminex; comparar as características da rejeição aguda mediada por anticorpo em relação à rejeição aguda celular; avaliar o impacto na incidência de rejeição aguda mediada por anticorpo após utilizar a prova cruzada por citometria de fluxo e pesquisa de anticorpo específico de doador pré-transplante em pacientes com histórico de exposição prévia à aloantígenos. Métodos: Foram avaliados 124 pacientes transplantados renais, com pesquisa de C4d em biópsias precoces em pacientes com disfunção do enxerto e pesquisa de anticorpo contra o doador quando o C4d foi positivo. A rejeição aguda mediada por anticorpo foi tratada com plasmaferese e imunoglobulina intravenosa. Resultados: Foi encontrada uma incidência de rejeição aguda de 18,8%, com frequência de episódios de rejeição aguda celular de 14,9% e de rejeição aguda mediada por anticorpo de 6.6%. Quando comparados com rejeição aguda celular, os episódios de rejeição aguda mediada por anticorpo foram mais precoces (12,5 versus 59,9 dias, p = NS), sendo mais frequentes em pacientes femininas (75% versus 29%, p = 0,05), com doadores falecidos (75% versus 33%, p = 0.09), com maior tempo de diálise (87,7 versus 47,4, p = 0,03), maior número de transfusões (4,6 versus 1,4, p = 0,02), maior atividade contra painel (28,0 versus 4,8, p = 0,03) e mais frequentemente retransplantados (50 versus 5,6%, p = 0,02). Função retardada do enxerto foi mais frequente nos pacientes com rejeição aguda mediada por anticorpo (100 versus 50%, p = 0,02). Todos os pacientes com rejeição aguda celular reverteram a função do enxerto após o tratamento, com sobrevida do enxerto, em um ano, de 100%. Entre os pacientes com rejeição aguda mediada por anticorpo, o tratamento com plasmaferese e imunoglobulina foi eficiente em reduzir os títulos de anticorpo específico de doador (2.605 versus 202 mpi, p < 0,001), mas 3/8 pacientes evoluíram para perda do enxerto, conferindo sobrevida do enxerto de 62,5% (p < 0,001). Conclusões: O uso rotineiro da pesquisa de C4d e anticorpo doador específico aumentou a incidência de rejeição aguda. A rejeição aguda mediada por anticorpo apresentou perfil clínico e resposta terapêutica diferentes da rejeição aguda celular, conferindo-lhe pior prognóstico e pior resposta terapêutica.

3.
HB cient ; 4(1): 78-85, jan.-abr. 1997. ilus
Article in Portuguese | LILACS | ID: lil-214119

ABSTRACT

A técnica do "DNA fingerprinting" foi desenvolvida a partir de 1985 e proporcionou uma grande inovaçao nos testes de paternidade. Até entao, tais testes eram realizados, principalmente, com base no estudo dos antígenos, de proteínas séricas e eritrocitárias e no sistema HLA. A técnica atual se baseia na análise direta da molécula de DNA humano, que possui diversas regioes polimórficas em tandem, que sao herdadas mendelianamente. O uso de sondas, que promovem a hibridizaçao destas regioes polimórficas, fornecem padroes de bandas diferentes de indivíduo para indivíduo. Baseada neste polimorfismo, a técnica do "DNA fingerprinting" tem sido utilizada com alto grau de especificidade e confiabilidade na resoluçao de problemas jurídicos e criminais, especialmente nos casos de paternidade duvidosa, e também como um importante auxiliar nos estudos de antropologia humana e até no combate à extinçao e ao comércio ilegal de animais.


Subject(s)
Humans , DNA Fingerprinting , Paternity
SELECTION OF CITATIONS
SEARCH DETAIL